Garden plumbing guide

How to install an outdoor tap

A garden tap is one of those jobs that takes a few hours but pays off for years. No more carting full watering cans from the kitchen or running a hose through a window. The main things to get right are the double-check valve (required under UK water regulations) and protecting the pipework before the first frost.

Inspired by a helpful YouTube guide. This walk-through draws on "How to Fit An Outside Tap: Full Installation Guide", which covers the full job from start to finish including the double-check valve and compression fittings. Useful for seeing how to route the pipe through the wall without leaving gaps around the sleeve.

1. Plan where the tap will go

Choose a position on an outside wall that is as close as possible to the internal stopcock or a convenient branch off the cold mains supply. The shorter the pipe run inside the house, the less heat you lose and the simpler the job. Most people position the outdoor tap near the kitchen or utility room where the cold water supply is already accessible.

Mark the position on the outside wall at a comfortable height - about 500mm from the ground is typical, high enough to fit a watering can underneath without stooping. Hold a drill bit against the outside wall and make sure the angle will clear any internal obstacles before you commit.

2. Turn off the water and drain the pipe

Locate the indoor stopcock and turn it off. Open a tap downstream of it to drain any water sitting in the pipe. This reduces the chance of a wet mess when you cut into the supply pipe to tee off.

Some houses have a secondary stopcock closer to the kitchen or utility room - worth having a look before assuming you need to turn the whole mains off. A service valve on the new branch is good practice anyway, so you can isolate just the garden tap when needed.

3. Drill the hole through the wall

Use a core drill (or a long masonry bit) to drill a hole through the wall. A 25mm hole is usually enough for 15mm copper pipe with a plastic sleeve around it. Drill on a slight downward angle from inside to outside so water cannot sit in the sleeve and seep back into the wall cavity.

In a cavity wall, check for insulation batts before you drill - they can wrap around the drill bit. Have someone outside ready to guide the drill bit as it breaks through, and slow down before the last bit to avoid a large chip on the outer face.

4. Run the pipe and fit a service valve

Cut into the indoor cold supply pipe and fit a tee piece with a service valve on the new branch. Use compression or push-fit fittings - both are reliable for this application. Run 15mm copper or plastic barrier pipe through the wall sleeve to the outside.

Keep the internal pipe run as tidy as possible. Clip it at regular intervals so it does not sag or vibrate when the water is running. Leave a small loop of pipe near the connection to absorb any movement over time.

5. Fit the double-check valve

Under UK Water Supply (Water Fittings) Regulations, any outside tap connected to the mains must have a double-check valve on the supply. This prevents garden chemicals, fertiliser water, or other contaminants from being siphoned back into the mains supply if pressure drops.

Fit the double-check valve on the inside, between the service valve and the wall. It should be accessible for inspection. Most outdoor tap kits include a double-check valve, but check before you buy - some budget kits do not. Fitting a tap without one is against regulations.

6. Mount and connect the tap

On the outside, fit the tap backplate to the wall with suitable fixings. On brick or masonry, use wall plugs and stainless steel screws. Run the pipe from the wall sleeve up to the tap fitting and tighten all connections.

Use PTFE tape on all threaded joints and check each compression fitting is hand-tight before tightening with a spanner. Do not overtighten compression fittings - about one and a quarter turns past hand-tight is usually enough. Overtightening distorts the olive and can cause drips later.

7. Turn the water back on and check for leaks

Turn the indoor stopcock back on slowly and check every joint inside before going outside. Run your fingers along all the connections while the pressure builds. Any joint that is weeping will make itself obvious fairly quickly.

Open the garden tap and let the water run to clear any debris from the pipe. Close it and leave the system under pressure for a few minutes, then recheck every joint. A drip from a compression fitting usually means another quarter-turn on the nut.

8. Insulate the pipe for winter

Once everything is working and dry, fit foam pipe insulation over the indoor section of pipe between the service valve and the wall. In a cold snap, the pipe inside an unheated garage or utility room can freeze just as easily as an outdoor one.

During a prolonged frost, close the indoor service valve and open the outdoor tap to drain the pipe section outside. This is the simplest and most reliable way to prevent a freeze-burst in an East Kent winter. Some people fit a garden tap cover over the outside fitting as extra protection.

When to call a handyman

Call Richard if the internal pipework is awkward to access, the wall is unusually thick (cavity wall with full fill insulation, for example), or you would rather have the whole job done in one visit than spend a weekend getting familiar with compression fittings. Fitting an outdoor tap is a reasonable DIY project, but only if you are comfortable cutting into live plumbing.