5% off for pensioners on every job

Laundry appliance guide

How to fit a tumble dryer vent

Running a vented tumble dryer without a proper duct sends warm, damp air straight into the room. It ends up on the walls and windows as condensation. Fitting a duct through the wall is not a big job, but getting the hole size right, the external grille properly sealed, and the hose running without kinks makes a real difference to how the dryer performs.

Inspired by a helpful YouTube guide. This guide draws on "How to Install a Tumble Dryer Vent" from Cliff Poulter, a UK-based DIY creator. The video shows the full process from drilling through brick to fitting the external louvred grille, and explains why keeping the flexible hose short and straight matters for airflow.

1. Confirm you have a vented dryer

There are three types of tumble dryer: vented, condenser, and heat pump. Only vented dryers need a wall duct. Condenser dryers collect moisture in a tank you empty after each load. Heat pump dryers do the same but use less electricity.

Check the dryer's manual or the label on the back. If it has an exhaust outlet at the rear (usually a round spigot, 100mm or 102mm in diameter), it is a vented dryer and needs a duct to outside. If there is no exhaust outlet, you have a condenser or heat pump model and no ductwork is needed.

2. Plan the duct route

The shortest, most direct route to the outside wall is always best. Longer runs and bends reduce airflow, and the dryer has to work harder. Most manufacturers recommend keeping the flexible hose under 2 metres. Every 90-degree bend counts as an extra half-metre or so of run.

Mark where you want the external grille to sit on the outside wall - ideally out of reach of heavy rain splash and not right next to a window. Then work back inside to confirm where the hole will come through. Check the internal position does not land behind the dryer itself or in an awkward corner.

3. Check the wall for pipes and cables

Before you drill anything, run a cable and pipe detector over the internal wall at the planned hole position. Electric cables often run vertically from sockets and switches. Water pipes can go in almost any direction in a utility room.

If the detector shows something in the way, adjust your position left or right by 100mm and check again. Take your time here - an unexpected cable or copper pipe is a problem you do not want to find halfway through a core drill.

4. Drill the vent hole

Check your dryer's manual for the required duct diameter - most UK vented dryers use a 100mm or 102mm outlet, so a 110mm hole gives a comfortable fit for the wall sleeve. Hire or borrow a core drill for this if you can; it cuts a clean circle in brick, block, or masonry in a couple of minutes.

Drill from inside first to establish the angle (keep it very slightly downward toward the outside to prevent rainwater sitting in the duct). Then complete from outside if the core drill does not go all the way through cleanly. Keep the drill steady and let the tool do the work.

5. Fit the external louvred grille

Push the wall sleeve (a short section of rigid duct) through the hole from inside, so the external end protrudes by about 10mm. Apply frame sealant or external silicone around the perimeter on the outside face, then press the louvred grille over the sleeve and screw or rawl-plug it to the wall.

Use a louvred grille rather than a mesh-type. Mesh blocks up with fluff and restricts airflow quickly. Louvres open when the dryer runs and close when it stops, which also stops cold draughts coming in.

6. Connect the flexible hose

Push one end of the foil flexible hose onto the dryer's exhaust outlet spigot and secure it with the jubilee clip or hose clamp provided. Push the other end onto the internal end of the wall sleeve and secure that in the same way.

Keep the hose as short and straight as possible. Avoid sharp bends - gentle curves are fine, right-angle kinks are not. If the hose is longer than you need, trim it rather than coiling the excess. A kinked or coiled hose restricts airflow noticeably.

7. Test and check the flap

Run the dryer on a short cycle and go outside to watch the external grille. The louvres should open under the airflow and close again when the dryer stops. If the flap is barely moving, check the hose for kinks and confirm the internal duct sleeve is not partially blocked with debris from drilling.

Also check inside around the wall sleeve while the dryer is running. Any escaping warm air suggests the hose connections are not fully sealed. Nip them up with the clamps and check again.

When to call a handyman

Thick solid brick walls and cavity walls can both be drilled with the right equipment, but if the wall is awkward to reach from the outside or if the cable detector keeps showing something in the way, it is worth getting Richard to take a look. The drilling part is usually the bit people are least comfortable doing themselves.

Need a tumble dryer vent fitted?

The Sandwich Handyman can drill the wall duct and fit the grille and hose in Sandwich, Deal, and the nearby villages. Supply your own kit or ask Richard to bring the parts.

Contact Richard